H03VV-F / H05VV-F
300/300 V & 300/500 V Multi-core\ flexible PVC cables
| -20/+90 °C | Flexible |

Application
Low voltages household appliances under medium mechanical stress.
Construction
Cu/LSZH
1- Conductor: Flexible Copper
2-Insulation: LSZH
3-Outer sheath : LSZH
Technical Data
Max. operating temperature 70ºC
Short circuit temperature: 160ºC
Details
| Construction | Cu/LSZH |
|---|---|
| Standard | BS EN 50525-2-11, TS EN 50525-2-11 |
| UK Code | 3182Y, 3183Y, 3184Y |
|
Cross-section (mm²) |
Reaction To Fire classification |
Cross-section (mm²) |
Reaction To Fire classification |
|
2×0,75 |
Eca |
4×0,75 |
Eca |
|
2×1 |
Eca |
4×1 |
Eca |
|
2×1,5 |
Eca |
4×1,5 |
Eca |
|
2×2,5 |
Eca |
4×2,5 |
Eca |
|
2×4 |
Eca |
4×4 |
Eca |
|
3×0,75 |
Eca |
5×0,75 |
Eca |
|
3×1 |
Eca |
5×1 |
Eca |
|
3×1,5 |
Eca |
5×1,5 |
Eca |
|
3×2,5 |
Eca |
5×2,5 |
Eca |
|
3×4 |
Eca |
5×4 |
Eca |
|
Nominal cross-section (mm²) |
Nominal Thickness of Insulation (mm) |
Approx. Diameter under sheath |
Approximate overall diameter (mm) |
Max. Conductor DC resistance at 20 ºC (ohm/km) |
Approximate net weight (kg/km) |
|
2×0,5* |
0,5 |
3,9 |
5,2 |
39 |
37 |
|
2×0,75* |
0,5 |
4,3 |
5,6 |
26 |
45 |
|
3×0,5* |
0,5 |
4,2 |
5,5 |
39 |
44 |
|
3×0,75* |
0,5 |
4,7 |
5,9 |
26 |
54 |
|
4×0,5* |
0,5 |
4,7 |
6,0 |
39 |
53 |
|
4×0,75* |
0,5 |
5,2 |
6,5 |
26 |
66 |
|
2×0,75 |
0,6 |
4,7 |
6,4 |
26 |
56 |
|
2×1 |
0,6 |
5,0 |
6,7 |
19,5 |
64 |
|
2×1,5 |
0,7 |
5,9 |
7,6 |
13,3 |
85 |
|
2×2,5 |
0,8 |
7,2 |
9,3 |
7,98 |
131 |
|
2×4 |
0,8 |
8,2 |
10,5 |
4,95 |
178 |
|
3×0,75 |
0,6 |
5,1 |
6,8 |
26 |
66 |
|
3×1 |
0,6 |
5,5 |
7,1 |
19,5 |
76 |
|
3×1,5 |
0,7 |
6,4 |
8,3 |
13,3 |
106 |
|
3×2,5 |
0,8 |
7,8 |
10,1 |
7,98 |
161 |
|
3×4 |
0,8 |
8,9 |
11,4 |
4,95 |
222 |
|
4×0,75 |
0,6 |
5,7 |
7,4 |
26 |
80 |
|
4×1 |
0,6 |
6,1 |
7,9 |
19,5 |
97 |
|
4×1,5 |
0,7 |
7,2 |
9,3 |
13,3 |
134 |
|
4×2,5 |
0,8 |
8,7 |
11,0 |
7,98 |
199 |
|
4×4 |
0,8 |
10,0 |
12,4 |
4,95 |
275 |
|
5×0,75 |
0,6 |
6,4 |
8,2 |
26 |
99 |
|
5×1 |
0,6 |
6,8 |
8,6 |
19,5 |
115 |
|
5×1,5 |
0,7 |
8,0 |
10,3 |
13,3 |
165 |
|
5×2,5 |
0,8 |
9,8 |
12,2 |
7,98 |
244 |
|
5×4 |
0,8 |
11,1 |
14,0 |
4,95 |
344 |
| *300/300 V | |||||
|
Conductor cross- sectional area |
Enclosed in Conduit in thermally insulating wall etc. |
|
|
Single Phase AC |
Three Phase AC |
|
|
0,5 |
3 |
3 |
|
0,75 |
6 |
6 |
|
1 |
10 |
10 |
|
1,25 |
13 |
– |
|
1,5 |
16 |
16 |
|
2,5 |
25 |
20 |
|
4 |
32 |
25 |
| The above table is in accordance with BS 7671:2018 | ||
|
Conductor cross- sectional area |
DC or single phase AC |
Three Phase AC |
|
mV/A/m |
mV/A/V |
|
|
0,5 |
93 |
80 |
|
0,75 |
62 |
54 |
|
1 |
46 |
40 |
|
1,25 |
37 |
– |
|
1,5 |
32 |
27 |
|
2,5 |
19 |
16 |
|
4 |
12 |
10 |
| The above table is in accordance with BS 7671:2018 | ||