H03V2V2H2-F / H05V2V2H2-F
300/300 V & 300/500 V flexible, flat heat resisting cables
| -20/+90 °C | Flexible |

Application
Low voltages household appliances under medium mechanical stress and low temperatures.
Construction
Cu/PVC/PVC
1- Conductor: Flexible Copper
2-Insulation: PVC
3- Outer sheath: PVC
Technical Data
Min. bending radius 3 x D (D: Overall diameter)
Max. operating temperature 90ºC
Short circuit temperature: 160ºC
Details
| Construction | Cu/PVC/PVC |
|---|---|
| Standard | BS EN 50525-2-11, TS EN 50525-2-11 |
|
Cross-section (mm²) |
Reaction To Fire classification |
|
2×0,5* |
Eca |
|
2×0,75* |
Eca |
|
2×0,75 |
Eca |
|
2×1 |
Eca |
|
Nominal cross-section (mm²) |
Nominal Thickness of Insulation (mm) |
Approximate overall diameter (mm) |
Max. Conductor DC resistance at 20 ºC (ohm/km) |
Current carrying capacity in air (A) |
Approximate net weight (kg/km) |
|
2×0,5* |
0,5 |
3.35×5.40 |
39 |
3 |
26 |
|
2×0,75* |
0,5 |
3.50×5.75 |
26 |
6 |
32 |
|
2×0,75 |
0,6 |
4.10×6.60 |
26 |
6 |
40 |
|
2×1 |
0,6 |
4.30×6.85 |
19,5 |
10 |
47 |
| *300/300 V (H03V2V2H2-F) | |||||